3-2-3. Simple Counter
The function of Simple Counter collects any information and provides the counting
about the traffic of the port, no matter the packet is good or bad.
In the Fig. 3-15, the window can show all ports’ counter information at the same time.
Each data field has 20-digit long. If the counting is overflow, the counter will be reset and
restart counting. The data is updated every time interval defined by the user. The Refresh
Interval is used to set the update frequency.
Function name:
Simple Counter
Function description:
Display the summary counting of each port’s traffic, including Tx Byte, Rx Byte, Tx
Packet, Rx Packet, Tx Collision and Rx Error Packet.
Fig. 3-15
Parameters description:
Packet:
Transmit:
The counting number of the packet transmitted.
Receive:
The counting number of the packet received.