SignaMax 065-7851 Technical Information Page 71

  • Download
  • Add to my manuals
  • Print
  • Page
    / 309
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 70
SIGNAMAX a.s.
Seat: Palackeho trida 38, 612 00 Brno, CZ l Office: Vlarska 22, P. O. Box 214, 658 14 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
65
Fig. 3-24
Parameter description:
Port 1-24:
Port number.
VLAN Aware:
Based on IEEE 802.1Q VLAN tag to forward packet
Ingress Filtering:
Discard other VLAN group packets, only forward this port joined VLAN group
packets
Frame Type:
All: Forward all tagged and untagged packets
Tagged: Forward tagged packets only and discard untagged packets
PVID:
This PVID range will be 1-4094. Before you set a number x as PVID, you have to
create a Tag-based VLAN with VID x. For example, if port x receives an untagged
packet, the switch will apply the PVID (assume as VID y) of port x to tag this
packet, the packet then will be forwarded as the tagged packet with VID y.
Role:
This is an egress rule of the port. Here you can choose Access, Trunk or Hybrid.
Trunk means the outgoing packets must carry VLAN tag header. Access means
the outgoing packets carry no VLAN tag header. If packets have double VLAN tags,
one will be dropped and the other will still be left. As to Hybrid, it is similar to Trunk,
and both of them will tag-out. When the port is set to Hybrid, its packets will be
untagged out if the VID of the outgoing packets with tag is the same as the one in
the field of Untag VID of this port.