3-2-3. Simple Counter
The function of Simple Counter is to collect any information and provide the
traffic counts of the port, no matter whether the packet is good or bad.
In the Fig. 3-10, the window can show all ports’ counter information at the
same time. Each data field is 12 digits long. If the counters overflow, the counter will
be reset and will restart counting. The data is updated every time interval as defined
by the user. The valid range is 3 to 10 seconds. The Refresh Interval is used to set
the update frequency. Default update time is 3 seconds.
Fig. 3-10
Function name:
Simple Counter
Function description:
Displays the summary counting of each port’s traffic, including Tx Byte, Rx
Byte, Tx Packet, Rx Packet, Tx Collision and Rx Error Packet.
Parameters description:
Tx Byte:
Total transmitted bytes.
Rx Byte:
Total received bytes.
Tx Packet:
The counted number of packets transmitted.
Page view 56