4-4-3. Factory Default
Function name:
Factory Default
Function description:
The Factory Default Configuration function can retrieve the switch’s default
setting to replace the working configuration. Except for the IP address setting,
all configurations will be restored to the factory default value when the user
runs the “Factory Default” function in the web UI. If the user prefers to restore
all configurations including the IP address setting to the factory default, press
the “RESET” button on the front panel.
Note: the “RESET” button must be pressed for longer than 3 seconds to
restore the factory default setting.