Hardened Managed Ethernet Switch
User’s Manual 120
Trunking
Port Trunking
Port Trunking
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2. Usage:
Use static-channel-group command to create a static aggregator, or add a
member port to an already-existing static aggregator.
Use the no static-channel-group command to detach the port from the
static aggregator.
3. Command Syntax:
static-channel-group <1-3>
no static-channel-group
<1-3> Channel group number.
Maximum 4 ports in static-channel-group 1 and static-channel-group 2.
Maximum 2 ports in static-channel-group 3
4. Example:
The following example adding the interface fe1 (port 1) to
static-channel-group 1:
switch_a(config)#interface fe1
switch_a(config-if)#static-channel-group 1
switch_a(config-if)#